MON–FRI 08:00–17:00 · SAT 08:00–12:00

uPVC · 50–500 MM · CLASS 4–20 · SANS 966-1

uPVC pressure pipe

Rigid, smooth-bore pressure pipe for water mains, bulk supply, reticulation and irrigation mains.

SIZES
50–500 mm (15 sizes)
CLASSES
4, 6, 9, 12, 16, 20
STANDARD
SANS 966-1
COLOUR
Light blue
LENGTH
6 m effective length; 5.8 m from 355 mm
JOINT
Socket with factory-fitted rubber seal
SATAS certified

SATAS-certified to SANS 966-1. Certificate SATAS 408/1, valid to 9 Oct 2027.

Stacks of blue PVC pipe in the Pipelink warehousePVC PIPE · GABORONE WAREHOUSE

OVERVIEW

What it is

Unplasticised PVC: rigid, strong pipe with a smooth inside wall. The smooth bore means water flows with little friction, so you lose less pressure over a long run and your pump works less hard. Designed for a service life of 50 years.

WHY SPECIFY IT

  • Smooth boreLow friction keeps pressure losses and pumping costs down.
  • No corrosionDoesn't rust or corrode, inside or out.
  • Quick to layEvery socket has a factory-fitted rubber seal: lubricate the spigot and push it home.
  • Wide pressure rangeFrom Class 4 to Class 20, sized to your network design.

APPLICATIONS

Where it's used

Municipal mains

Municipal and village water mains.

Bulk supply

Bulk water supply from source to reservoir.

Reticulation

Distribution networks to stands and homes.

Irrigation mains

Main and sub-main lines on irrigation schemes.

Pumped lines

Pumped water lines and sewage rising mains.

SIZES AND DATA

Sizes, classes and data

uPVC pressure pipe · SANS 966-1Each cell: minimum wall thickness, then mass per pipe. – means not made in that size and class.
SIZE (OD)CLASS 4CLASS 6CLASS 9CLASS 12CLASS 16CLASS 20LENGTH
50 mm1.5 mm2.0 kg1.8 mm2.4 kg2.2 mm2.9 kg2.8 mm3.6 kg3.7 mm4.7 kg–6 m
63 mm1.5 mm2.5 kg1.9 mm3.2 kg2.7 mm4.5 kg3.6 mm5.9 kg4.7 mm7.5 kg–6 m
75 mm1.5 mm3.0 kg2.2 mm4.3 kg3.2 mm6.2 kg4.3 mm8.2 kg5.6 mm10.5 kg6.9 mm12.7 kg6 m
90 mm1.8 mm4.4 kg2.7 mm6.5 kg3.9 mm9.3 kg5.1 mm11.9 kg6.7 mm15.4 kg8.2 mm18.5 kg6 m
110 mm2.2 mm6.5 kg2.6 mm7.7 kg3.9 mm11.4 kg5.1 mm14.8 kg6.7 mm19.1 kg8.2 mm23.1 kg6 m
125 mm2.5 mm8.5 kg3.0 mm10.1 kg4.4 mm14.7 kg5.8 mm19.1 kg7.6 mm24.7 kg9.3 mm29.7 kg6 m
140 mm2.8 mm10.6 kg3.3 mm12.5 kg4.9 mm18.3 kg6.5 mm24.0 kg8.5 mm30.9 kg10.4 mm37.3 kg6 m
160 mm3.2 mm13.9 kg3.8 mm16.4 kg5.6 mm24.0 kg7.4 mm31.3 kg9.7 mm40.4 kg11.9 mm48.8 kg6 m
200 mm3.9 mm21.2 kg4.7 mm25.5 kg7.0 mm37.5 kg9.2 mm48.7 kg12.1 mm63.1 kg14.9 mm76.6 kg6 m
250 mm4.9 mm33.4 kg5.9 mm40.1 kg8.7 mm58.5 kg11.5 mm76.4 kg15.1 mm98.8 kg18.6 mm119.8 kg6 m
315 mm6.2 mm53.5 kg7.4 mm63.6 kg11.0 mm93.5 kg14.5 mm121.8 kg19.0 mm157.2 kg–6 m
355 mm7.0 mm66.1 kg8.4 mm79.0 kg12.4 mm115.3 kg16.3 mm149.8 kg21.4 mm193.7 kg–5.8 m
400 mm7.8 mm83.2 kg9.4 mm99.9 kg14.0 mm147.0 kg18.4 mm191.0 kg24.1 mm246.4 kg–5.8 m
450 mm8.9 mm107.1 kg10.6 mm127.0 kg15.7 mm186.0 kg20.7 mm242.4 kg––5.8 m
500 mm9.8 mm131.5 kg11.8 mm157.7 kg17.4 mm229.8 kg22.9 mm299.0 kg––5.8 m

Minimum wall thickness and mass per pipe. Pipe lengths are effective lengths, excluding the socket.

STANDARDS

Certified to SANS 966-1

Product certification by SATAS, an independent certification body, against the South African National Standard for this pipe.

SATAS certifiedSANS 966-1
uPVC pressure pipe
CERTIFICATESATAS 408/1
VALID TO9 Oct 2027
QUALITY SYSTEMSABS ISO 9001:2015 · LS 5769

HANDLING AND INSTALLATION

Good practice on site

General guidance for storing and laying uPVC pipe. Always follow the project specification and the relevant installation standard.

  • Support pipes evenly along their full length when stacked; keep stacks low and on a flat surface.
  • Alternate sockets when stacking so they don't carry the load, and protect pipe ends.
  • Don't drop pipes onto hard surfaces or drag them. Lift and place them.
  • Limit storage in direct sunlight, and keep sockets and their rubber seals clean.
  • Lubricate the spigot and push it fully home into the next socket.
  • PVC is less impact-resistant in cold weather, so handle it with extra care on cold mornings.
  • Lay pipe on bedding free of stones and follow the engineer's specification for bedding and backfill.

QUESTIONS

Before you order

More answers in the technical guide.

Which class do I need?

Pick a class above the highest working pressure in your line, including pump pressure and surge. Class is the working pressure in bar at 20 °C: Class 6 is rated to 6 bar, about 60 m of head. Tell us the pump and the run and we'll recommend one.

uPVC or mPVC?

Both are certified pressure pipe. mPVC is tougher and lighter for the same class; uPVC is the proven standard and the only one of the two made in Class 4. If your trench is rocky or the pipe will be handled roughly, choose mPVC.

How long are the pipes?

uPVC, mPVC and sewer pipe: 6 m effective length up to 315 mm, and 5.8 m from 355 to 500 mm. Effective length is measured up to the socket, so it's the length each pipe adds to your line. SWV comes in 6 m lengths and conduit in 4 m lengths.

How do the pipes join?

Each uPVC, mPVC and sewer pipe has a socket with a factory-fitted rubber seal: lubricate the spigot end and push it into the next socket.

How long does it last?

uPVC and mPVC pressure pipe are designed for a service life of 50 years.

Do you deliver?

Yes. We deliver across Botswana, and we also export to South Africa. Tell us the site when you ask for a quote.

Need uPVC pipe? Tell us the size, class and quantity.

Every quote is built for the order. We don't publish prices, but we answer quickly.